<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	>

<channel>
	<title>Substruct Knowledge Base</title>
	<atom:link href="http://substructsystems.com/kb/index.php/feed/" rel="self" type="application/rss+xml" />
	<link>http://substructsystems.com/kb</link>
	<description>Tutorials, Help Files, and Documentation for Substruct Utilities, Cougar Mountain, and more.</description>
	<pubDate>Thu, 25 Jun 2009 15:47:21 +0000</pubDate>
	<generator>http://wordpress.org/?v=2.5.1</generator>
	<language>en</language>
			<item>
		<title>File sharing lock count exceeded</title>
		<link>http://substructsystems.com/kb/index.php/file-sharing-lock-count-exceeded/</link>
		<comments>http://substructsystems.com/kb/index.php/file-sharing-lock-count-exceeded/#comments</comments>
		<pubDate>Thu, 25 Jun 2009 15:47:21 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Knowledge Base]]></category>

		<category><![CDATA[Access 97]]></category>

		<category><![CDATA[File Sharing Lock Count]]></category>

		<category><![CDATA[Record locks]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=133</guid>
		<description><![CDATA[


File sharing lock count exceeded (Error 3052).


The error may also occur when you run a Visual Basic for Applications procedure that uses the Synchronize method.
Back to the top

CAUSE
A member of the replica set contains too many changes for synchronization to be completed successfully. For example, if one of the replicas has increased in size by [...]]]></description>
			<content:encoded><![CDATA[<div class="sbody">
<div class="kb_errormsgbody">
<div class="kb_errorcontent">
<div class="errormsg">File sharing lock count exceeded (Error 3052).</div>
</div>
</div>
<p>The error may also occur when you run a Visual Basic for Applications procedure that uses the Synchronize method.</p>
<div class="topOfPage"><a href="http://support.microsoft.com/kb/173006#top"><img src="http://support.microsoft.com/library/images/support/kbgraphics/public/en-us/uparrow.gif" alt="" />Back to the top</a></div>
</div>
<h2 id="tocHeadRef" class="subTitle"><span><a href="javascript:void(0);">CAUSE</a></span></h2>
<div class="sbody">A member of the replica set contains too many changes for synchronization to be completed successfully. For example, if one of the replicas has increased in size by 100 megabytes (MB) because you have added a large number of new records, you may receive this error. The replica that contains too many changes may be the database from which you are attempting to synchronize, or it may also be another member of the replica set.</p>
<div class="topOfPage"><a href="http://support.microsoft.com/kb/173006#top"><img src="http://support.microsoft.com/library/images/support/kbgraphics/public/en-us/uparrow.gif" alt="" />Back to the top</a></div>
</div>
<h2 id="tocHeadRef" class="subTitle"><span><a href="javascript:void(0);">RESOLUTION</a></span></h2>
<div class="sbody">If you are using Microsoft Access 97, you can take advantage of a new feature that allows you to increase the MaxLocksPerFile setting for Microsoft Jet database engine 3.5 by editing the Windows Registry. The default value of this setting is 9500. However, changing this value is not recommended if one of the replicas is located on a Novell Netware server because the server&#8217;s maximum record locks per connection is 10000. In addition, changing this value will result in poor performance if one of the replicas is located on a server running Windows NT version 3.51 or earlier. If both replicas are located on servers running Microsoft Windows NT version 4.0 or Microsoft Windows 95, the maximum value of this setting is limited only by available resources.Â </p>
<p>WARNING: Modifications made to the system registry are considered advanced usage of the Windows 95 or Windows NT operating systems. Extreme care should be taken when making modifications. Any invalid or incorrect entries may render the operating system unusable.Â </p>
<p>WARNING: Using Registry Editor incorrectly can cause serious problems that may require you to reinstall Windows 95. Microsoft cannot guarantee that problems resulting from the incorrect use of Registry Editor can be solved. Use Registry Editor at your own risk.Â </p>
<p>For information about how to edit the registry, view the Changing Keys And Values Help topic in Registry Editor (Regedit.exe). Note that you should make a backup copy of the registry files (System.dat and User.dat) before you edit the registry.Â </p>
<ol>
<li>Quit Microsoft Access.</li>
<li>Click the Start button, and then click Run.</li>
<li>In the Open box, typeÂ <span class="userInput">regedit</span>.</li>
<li>Locate the HKEY_LOCAL_MACHINE registry folder.</li>
<li>Expand the HKEY_LOCAL_MACHINE folder until you locate the folder SOFTWARE\Microsoft\Jet\3.5\Engines\Jet 3.5.</li>
<li>Double-click the Jet 3.5 folder to view its contents.</li>
<li>Select the MaxLocksPerFile entry; on the Edit menu, click Modify.</li>
<li>In the Edit DWORD Value dialog box, select Decimal and increase the number in the Value Data box.</li>
<li>Click OK to save the MaxLocksPerFile setting.</li>
<li>Quit the Registry Editor.</li>
<li>Start Microsoft Access and synchronize the replicas.</li>
</ol>
</div>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/file-sharing-lock-count-exceeded/feed/</wfw:commentRss>
		</item>
		<item>
		<title>&#8220;Object reference not set to an instance of an object.&#8221; when opening Substruct on a workstation.</title>
		<link>http://substructsystems.com/kb/index.php/object-reference-not-set-to-an-instance-of-an-object-when-opening-substruct-on-a-workstation/</link>
		<comments>http://substructsystems.com/kb/index.php/object-reference-not-set-to-an-instance-of-an-object-when-opening-substruct-on-a-workstation/#comments</comments>
		<pubDate>Thu, 22 Jan 2009 18:22:52 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Knowledge Base]]></category>

		<category><![CDATA[Substruct]]></category>

		<category><![CDATA[Substruct Utilities]]></category>

		<category><![CDATA[Troubleshoot]]></category>

		<category><![CDATA[Error]]></category>

		<category><![CDATA[Object]]></category>

		<category><![CDATA[XP]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=132</guid>
		<description><![CDATA[This error is easily fixed by installing XP SP3 on your workstation.
]]></description>
			<content:encoded><![CDATA[<p>This error is easily fixed by installing XP SP3 on your workstation.</p>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/object-reference-not-set-to-an-instance-of-an-object-when-opening-substruct-on-a-workstation/feed/</wfw:commentRss>
		</item>
		<item>
		<title>Substruct won&#8217;t open on a computer over the network (The application failed to initialize properly)properly</title>
		<link>http://substructsystems.com/kb/index.php/substruct-wont-open-on-a-computer-over-the-network-the-application-failed-to-initialize-properlyproperly/</link>
		<comments>http://substructsystems.com/kb/index.php/substruct-wont-open-on-a-computer-over-the-network-the-application-failed-to-initialize-properlyproperly/#comments</comments>
		<pubDate>Tue, 13 Jan 2009 20:29:03 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Knowledge Base]]></category>

		<category><![CDATA[Substruct]]></category>

		<category><![CDATA[Substruct Utilities]]></category>

		<category><![CDATA[Troubleshoot]]></category>

		<category><![CDATA[.NET]]></category>

		<category><![CDATA[application failed to initialize properly]]></category>

		<category><![CDATA[substruct.exe]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=129</guid>
		<description><![CDATA[Problem
When trying to run Substruct Utiilities (substruct.exe) over the network for the first time, you may receive an error:
The application failed to initialize properly (oxc0000135). Click on OK to terminate the application.
This is due to the Microsoft .NET Framework Runtime Security Policy no being configured correctly.
Solution
On a Windows XP computer, do the following:
1. Open Control [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Problem</strong><br />
When trying to run Substruct Utiilities (substruct.exe) over the network for the first time, you may receive an error:</p>
<blockquote><p>The application failed to initialize properly (oxc0000135). Click on OK to terminate the application.</p></blockquote>
<p>This is due to the Microsoft .NET Framework Runtime Security Policy no being configured correctly.</p>
<p><strong>Solution</strong><br />
On a Windows XP computer, do the following:<br />
1. Open Control Panel.<br />
2. Open Administrative Tools.<br />
3. Open Microsoft .NET Framework 1.1 Configuration.<br />
4. Expand Runtime Security Policy.<br />
5. Expand Machine.<br />
6. Expand Code Groups.<br />
7. Right-click on All_Code and click Properties.<br />
8. Click the Permission Set tab.<br />
9. Change the Permission Set drop down to &#8220;Full Trust&#8221;.<br />
10. Click OK to save this change.<br />
11. Close the .NET Configuration 1.1 window.</p>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/substruct-wont-open-on-a-computer-over-the-network-the-application-failed-to-initialize-properlyproperly/feed/</wfw:commentRss>
		</item>
		<item>
		<title>Adjust Barcode Scanner to be always on</title>
		<link>http://substructsystems.com/kb/index.php/adjust-barcode-scanner-to-be-always-on/</link>
		<comments>http://substructsystems.com/kb/index.php/adjust-barcode-scanner-to-be-always-on/#comments</comments>
		<pubDate>Tue, 13 Jan 2009 02:11:23 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Knowledge Base]]></category>

		<category><![CDATA[Point of Sale]]></category>

		<category><![CDATA[3800g]]></category>

		<category><![CDATA[automatic trigger]]></category>

		<category><![CDATA[barcode]]></category>

		<category><![CDATA[Handheld]]></category>

		<category><![CDATA[honeywell]]></category>

		<category><![CDATA[manual trigger]]></category>

		<category><![CDATA[presentation mode]]></category>

		<category><![CDATA[scan]]></category>

		<category><![CDATA[scanner]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=128</guid>
		<description><![CDATA[To make your Handheld (Honeywell) 3800g barcode scanner stay on all the time (great for when inside a craddle or stand), scan the &#8220;Automatic Trigger&#8221; barcode bellow.

]]></description>
			<content:encoded><![CDATA[<p>To make your Handheld (Honeywell) 3800g barcode scanner stay on all the time (great for when inside a craddle or stand), scan the &#8220;Automatic Trigger&#8221; barcode bellow.</p>
<p><a href="http://substructsystems.com/kb/wp-content/uploads/2009/01/trigger.bmp"><img class="aligncenter size-full wp-image-127" title="trigger" src="http://substructsystems.com/kb/wp-content/uploads/2009/01/trigger.bmp" alt="" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/adjust-barcode-scanner-to-be-always-on/feed/</wfw:commentRss>
		</item>
		<item>
		<title>POS sales &#8220;cashes out&#8221; in the middle of sale</title>
		<link>http://substructsystems.com/kb/index.php/pos-sales-cashes-out-in-the-middle-of-sale/</link>
		<comments>http://substructsystems.com/kb/index.php/pos-sales-cashes-out-in-the-middle-of-sale/#comments</comments>
		<pubDate>Sun, 11 Jan 2009 00:21:05 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Cougar Mountain]]></category>

		<category><![CDATA[Knowledge Base]]></category>

		<category><![CDATA[Point of Sale]]></category>

		<category><![CDATA[Troubleshoot]]></category>

		<category><![CDATA[3800]]></category>

		<category><![CDATA[3800g]]></category>

		<category><![CDATA[barcode]]></category>

		<category><![CDATA[Cash out]]></category>

		<category><![CDATA[close out]]></category>

		<category><![CDATA[Drawer]]></category>

		<category><![CDATA[Handheld]]></category>

		<category><![CDATA[Open]]></category>

		<category><![CDATA[POS]]></category>

		<category><![CDATA[scanner]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=126</guid>
		<description><![CDATA[
This problem is due to items being scanned too quickly in Cougar Mountain. To prevent this, adjust the &#8220;Reread&#8221; and &#8220;Good Read&#8221; delays on your barcode scanner. For the Handheld 3800g (Substruct&#8217;s recommend barcode imaging device) print or scan the barcode bellow. &#8220;Medium&#8221; speed is recommended for both.



]]></description>
			<content:encoded><![CDATA[<div>
<p>This problem is due to items being scanned too quickly in Cougar Mountain. To prevent this, adjust the &#8220;Reread&#8221; and &#8220;Good Read&#8221; delays on your barcode scanner. For the Handheld 3800g (Substruct&#8217;s recommend barcode imaging device) print or scan the barcode bellow. &#8220;Medium&#8221; speed is recommended for both.</p>
</div>
<p><a href="http://substructsystems.com/kb/wp-content/uploads/2009/01/goodread.bmp"><img class="aligncenter size-full wp-image-124" title="goodread" src="http://substructsystems.com/kb/wp-content/uploads/2009/01/goodread.bmp" alt="" /></a><br />
<a href="http://substructsystems.com/kb/wp-content/uploads/2009/01/reread.bmp"><img class="aligncenter size-full wp-image-125" title="reread" src="http://substructsystems.com/kb/wp-content/uploads/2009/01/reread.bmp" alt="" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/pos-sales-cashes-out-in-the-middle-of-sale/feed/</wfw:commentRss>
		</item>
		<item>
		<title>AR Totals are incorrect or they don&#8217;t match the invoices dues.</title>
		<link>http://substructsystems.com/kb/index.php/ar-totals-are-incorrect-or-they-dont-match-the-invoices-dues/</link>
		<comments>http://substructsystems.com/kb/index.php/ar-totals-are-incorrect-or-they-dont-match-the-invoices-dues/#comments</comments>
		<pubDate>Wed, 03 Sep 2008 21:10:17 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Accounts Receivable]]></category>

		<category><![CDATA[Cougar Mountain]]></category>

		<category><![CDATA[Troubleshoot]]></category>

		<category><![CDATA[AR]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=122</guid>
		<description><![CDATA[Occasionally, Accounts Receivable total will be off. This is caused by Cougar Mountain forÂ unknownÂ reasons. To check forÂ discrepancies, do the following:

In AR, go to Reports &#62; Control. ClickÂ OKÂ to run the report.

If their are errors orÂ discrepancies, do the following:



In AR, go to Options &#62; FileÂ MaintenanceÂ &#62; Recalculate Master File&#8230;
From here you can either enter in the customer&#8217;s account [...]]]></description>
			<content:encoded><![CDATA[<p>Occasionally, Accounts Receivable total will be off. This is caused by Cougar Mountain forÂ unknownÂ reasons. To check forÂ discrepancies, do the following:</p>
<ul>
<li>In AR, go to <strong>Reports &gt; Control</strong>. ClickÂ <strong>OK</strong>Â to run the report.</li>
</ul>
<div>If their are errors orÂ discrepancies, do the following:</div>
<div></div>
<div>
<ul>
<li>In AR, go to <strong>Options &gt; FileÂ MaintenanceÂ &gt; Recalculate Master File&#8230;</strong></li>
<li>From here you can either enter in the customer&#8217;s account number, or rebuild the totals for every customer. It is recommended that you do this when you are closed and not using Cougar Mountain on other computers.</li>
</ul>
</div>
<p>Â</p>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/ar-totals-are-incorrect-or-they-dont-match-the-invoices-dues/feed/</wfw:commentRss>
		</item>
		<item>
		<title>Short barcodes are not scanning correctly</title>
		<link>http://substructsystems.com/kb/index.php/short-barcodes-are-not-scan-correctly/</link>
		<comments>http://substructsystems.com/kb/index.php/short-barcodes-are-not-scan-correctly/#comments</comments>
		<pubDate>Thu, 28 Aug 2008 19:20:44 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Knowledge Base]]></category>

		<category><![CDATA[Symbol]]></category>

		<category><![CDATA[Troubleshoot]]></category>

		<category><![CDATA[barcode]]></category>

		<category><![CDATA[scan]]></category>

		<category><![CDATA[scanner]]></category>

		<category><![CDATA[UPCA]]></category>

		<category><![CDATA[UPCE]]></category>

		<category><![CDATA[UPCE0]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=121</guid>
		<description><![CDATA[Short barcodes on someÂ merchandiseÂ may not scan correctly by default. These barcodes use the UPCE (usually UPCE0) symbology, and most aliases are stored in your Cougar Mountain installation in the standard 12 digit UPCA format. For reference, Ace sends down UPCÂ informationÂ in UPCA format. To enable your scanner to convert UPCE to UPCA, do the following:

Symbol MC50 [...]]]></description>
			<content:encoded><![CDATA[<p>Short barcodes on someÂ merchandiseÂ may not scan correctly by default. These barcodes use the UPCE (usually UPCE0) symbology, and most aliases are stored in your Cougar Mountain installation in the standard 12 digit UPCA format. For reference, Ace sends down UPCÂ informationÂ in UPCA format. To enable your scanner to convert UPCE to UPCA, do the following:</p>
<div>
<h3>Symbol MC50 or MC9000 handheld scanners</h3>
<ul>
<li>From the Start screen, click on Scan Wedge in the bottom right hand corner of the home screen.</li>
<li>ClickÂ Config</li>
<li>ClickÂ Codes</li>
<li>Make sureÂ UPCE0Â is checked</li>
<li>HighlightÂ UPCE0Â and clickÂ ParamÂ </li>
<li>ClickÂ Cnvt to UPCAÂ to switch the value toÂ True.</li>
</ul>
<h3>Handheld Products (or Honeywell) 3800G</h3>
<p>Print and scan the following &#8220;On&#8221; barcode.</p>
<p><a href="http://substructsystems.com/kb/wp-content/uploads/2008/08/upcetoupca.bmp"><img class="size-full wp-image-120 alignleft" style="float: left; " title="upcetoupca" src="http://substructsystems.com/kb/wp-content/uploads/2008/08/upcetoupca.bmp" alt="Config Handheld Products 3800g for UPCE" /></a></p>
<p>Â </p>
<p>Â </p>
<p>ï¿½</p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/short-barcodes-are-not-scan-correctly/feed/</wfw:commentRss>
		</item>
		<item>
		<title>Tools Menu</title>
		<link>http://substructsystems.com/kb/index.php/tools-menu/</link>
		<comments>http://substructsystems.com/kb/index.php/tools-menu/#comments</comments>
		<pubDate>Thu, 28 Aug 2008 13:55:04 +0000</pubDate>
		<dc:creator>Jeff Churchill</dc:creator>
		
		<category><![CDATA[Tools]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=53</guid>
		<description><![CDATA[The Tools menu contains links to the Signs and Labels programs, both of which can also be found on the Switchboard. It also has a links to the Customer Rewards utility, the Barcode Generator, and the Register Item Sheet tool.
]]></description>
			<content:encoded><![CDATA[<p>The <strong>Tools</strong> menu contains links to the <strong>Signs</strong> and <strong>Labels</strong> programs, both of which can also be found on the <strong>Switchboard</strong>. It also has a links to the <strong>Customer Rewards</strong> utility, the <strong>Barcode Generator</strong>, and the <strong>Register Item Sheet</strong> tool.</p>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/tools-menu/feed/</wfw:commentRss>
		</item>
		<item>
		<title>Text will not print on wireless label printer.</title>
		<link>http://substructsystems.com/kb/index.php/text-will-not-print-on-wireless-label-printer/</link>
		<comments>http://substructsystems.com/kb/index.php/text-will-not-print-on-wireless-label-printer/#comments</comments>
		<pubDate>Tue, 26 Aug 2008 21:05:45 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Knowledge Base]]></category>

		<category><![CDATA[Substruct]]></category>

		<category><![CDATA[Substruct Mobile]]></category>

		<category><![CDATA[Zebra]]></category>

		<category><![CDATA[Label Vista]]></category>

		<category><![CDATA[Labels]]></category>

		<category><![CDATA[QL320]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=113</guid>
		<description><![CDATA[
The .cpf font files need to be loaded on to the printer using Zebra&#8217;s Label Vista software. Contact technical support for assistance with this.
]]></description>
			<content:encoded><![CDATA[<p><a href="http://substructsystems.com/kb/wp-content/uploads/2008/08/arial9.cpf"></a></p>
<p>The .cpf font files need to be loaded on to the printer using Zebra&#8217;s Label Vista software. Contact technical support for assistance with this.</p>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/text-will-not-print-on-wireless-label-printer/feed/</wfw:commentRss>
		</item>
		<item>
		<title>Setting up a Zebra Label Printer</title>
		<link>http://substructsystems.com/kb/index.php/setting-up-a-zebra-label-printer/</link>
		<comments>http://substructsystems.com/kb/index.php/setting-up-a-zebra-label-printer/#comments</comments>
		<pubDate>Fri, 15 Aug 2008 16:02:04 +0000</pubDate>
		<dc:creator>Luke Stratton</dc:creator>
		
		<category><![CDATA[Zebra]]></category>

		<category><![CDATA[Label Vista]]></category>

		<category><![CDATA[Labels]]></category>

		<category><![CDATA[QL320]]></category>

		<category><![CDATA[Substruct Mobile]]></category>

		<category><![CDATA[Wireless]]></category>

		<category><![CDATA[WPA]]></category>

		<guid isPermaLink="false">http://substructsystems.com/kb/?p=108</guid>
		<description><![CDATA[The Zebra QL320 must be configured with a serial cable (to order one, give us a call).
Then the Label Vista must be downloaded from Zebra&#8217;s website (www.zebra.com) and installed on the computer you are using to setup the printer.
We recommend that you use some for of wireless encryption. WPA is more secure than WEP, and [...]]]></description>
			<content:encoded><![CDATA[<p>The Zebra QL320 must be configured with a serial cable (to order one, give us a call).</p>
<p>Then the <strong>Label Vista</strong> must be downloaded from Zebra&#8217;s website (<a href="http://www.zebra.com">www.zebra.com</a>) and installed on the computer you are using to setup the printer.</p>
<p>We recommend that you use some for of wireless encryption. WPA is more secure than WEP, and it also makes setting upÂ laptops and other mobile devices easier (just give the user the pass phrase).</p>
<h2>Setup your router&#8217;s wireless network</h2>
<p>For a Linksys wirelessÂ router such as the WRT54G (or most wireless routers for that matter)Â you will need to set the following:</p>
<ul>
<li>SSID: The name of your wireless network (i.e. <strong>AceHardware</strong>, <strong>SmallTownHardware</strong>, etc.)</li>
<li>Set the security to <strong>WPA Personal</strong>.</li>
<li>Set the WPA Algorithms to <strong>TKIP</strong>.</li>
<li>Set the WPA shared key to an 8 character password of your choice (i.e. <strong>ace54321</strong>, <strong>1337pass</strong>).</li>
</ul>
<p style="text-align: center;"><a href="http://substructsystems.com/kb/wp-content/uploads/2008/08/linksys1.jpg"><img class="size-full wp-image-110" title="linksys1" src="http://substructsystems.com/kb/wp-content/uploads/2008/08/linksys11.jpg" alt="" width="471" height="414" /></a></p>
<h2>Â Configure your QL320 printer with Label Vista</h2>
<ul>
<li>Plug in your printer.</li>
<li>Make sure Label Vista is set to use the correct Com port.</li>
<li>Go to <strong>Printer &gt; Network Settings</strong>.</li>
<li style="text-align: left;">Fill in your network settings. Make sure you set the IP address to be the same as it is in Substruct Utilities preferences (usually 192.168.X.100)</li>
</ul>
<p style="text-align: center;"><a href="http://substructsystems.com/kb/wp-content/uploads/2008/08/label-vista1.jpg"><img class="aligncenter size-full wp-image-111" title="label-vista1" src="http://substructsystems.com/kb/wp-content/uploads/2008/08/label-vista1.jpg" alt="" width="500" height="404" /></a></p>
<ul>
<li>
<div style="text-align: left;">Next, configure the WPA security.</div>
</li>
<li>
<div style="text-align: left;">Set the Mode to <strong>WPA</strong></div>
</li>
<li>
<div style="text-align: left;">Set Authentication to <strong>PSK</strong></div>
</li>
<li>
<div style="text-align: left;">Set PSK to <strong>Ascii</strong> and then enter you pass phrase.</div>
</li>
<li>
<div style="text-align: left;">Click <strong>OK </strong>or <strong>Apply</strong> to send the changes to the printer.</div>
</li>
</ul>
<p style="text-align: center;"><a href="http://substructsystems.com/kb/wp-content/uploads/2008/08/label-vista2.jpg"><img class="alignnone size-full wp-image-112" title="label-vista2" src="http://substructsystems.com/kb/wp-content/uploads/2008/08/label-vista2.jpg" alt="" width="500" height="404" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://substructsystems.com/kb/index.php/setting-up-a-zebra-label-printer/feed/</wfw:commentRss>
		</item>
	</channel>
</rss>
